Sign In | Join Free | My enlightcorp.com |
|
Brand Name : Delta
Model Number : CPT-III
Certification : ISO9001
Place of Origin : China
MOQ : 1 set Relay Tester
Price : USD1.0
Payment Terms : T/T, Western Union
Supply Ability : 1000 sets per month
Delivery Time : 10-20 days
Packaging Details : CPT-III Current Transformer Testing packed in veneer case
Item Name : CPT-III 220V to 500kv Power Current Transformer Testing Equipment
Functions : Test parameters of various kinds of transformer
Description : Power Current Transformer Testing Equipment
Knee Point Voltage : 40kV
Max. Test Voltage : 180V
Size : 485mm×356mm×183mm
Weight : <15kg
Power supply : AC220V ± 10%, 50Hz/60Hz
Warranty : One year
Service : OEM service is available
CPT-III Power Current Transformer Testing Equipment is used to measure all kinds of current transformer and voltage transformer.
CPT-III Power Current Transformer Testing Equipment can calculate the ratio errors and phase angle errors of current transformer and voltage transformer at rated burden and working burden in one test.
CPT-III Power Current Transformer Testing Equipment can automatically evaluate the test results according to the selected standard to determine whether the transformer is qualified.
Tests for current transformer:
Tests for voltage transformer:
Applications for CTPT analyzer:
PT routine test
1 | Test standards | IEC60044-1, IEC60044-6, GB1208, GB16847, C57.13 |
2 | Power supply | AC220V±10%,50Hz/60Hz±10% |
3 | Power output | 0.1~180V (AC) |
4 | Current output | 0.001~5A(RMS) |
5 | Power output | 300VA |
6 | Max. knee voltage measurement | 45kv |
7 | Current measurement range | 0~10A (automatically change range in 0.1/0.4/2/10A) |
8 | Current measurement error | <±0.1%+0.01%FS |
9 | Voltage measurement range | 0~200 V (automatically change range in 1V/10V/70V/200V) |
10 | Voltage measurement error | < ±0.1%+0.01%FS |
11 | Turns ratio measurement range | 1~35000; 1~2000 error<0.05%; 2000~5000 error>0.1%; 5000~35000 error<0.2% |
12 | Phase measurement | error:±2min,resolution:0.01min |
13 | Coil resistance measurement | Range: 0~8kΩ(automatically change range in 2ohm /20ohm /80ohm/800ohm/8kohm) Error< 0.2%RDG+0.02%FS Maximum resolution: 0.1mΩ |
14 | Temperature measurement | -50~100 Celsius degree, error<3 Celsius degree |
15 | CT Secondary burden | Range 0-160ohm (automatically change range in 2ohm/ 20ohm/80ohm/160ohm) Error <0.2%RDG+0.02%FS Maximum resolution 0.001ohm |
16 | PT Secondary burden | Range 0-80kohm (automatically change range in 800ohm / 8kohm /80kohm) Error <0.2%RDG+0.02%FS Maximum resolution: 0.1ohm |
17 | PT ratio measurement | Range: 1~35000, 1~5000 error<0.2% 5000~35000 error<0.5% |
18 | Saved data groups | >1000groups |
19 | Work condition | Temperature:-10℃-50℃, moist:≤90% |
20 | Size | 485mm×356mm×183mm |
21 | Weight | <15Kg |
![]() |
CPT-III 220V to 500kv Power Current Transformer Testing Equipment Images |